Influence of Lampholders on Irradiation Intensityof Ultraviolet Disinfection Lamps |
CHEN Chao, AN Daizhi, XU Xiaoyan, YANG Wenwen, LI Dandan, LI Suolan |
Medical Clinic, Political Work Department of Central Military Commission, Beijing 100120, China |
|
|
Abstract Objective To investigate the reasons for low radiation intensity of standard UV disinfection lamps in military catering units so as to take effective measures accordingly.Methods After causes associated with voltage, temperature, humidity, quality of ultraviolet lamps were excluded, the ultraviolet radiation intensity of thirty newly-purchased 500 h, 40 W UV lamps, which were used in catering units and medical institutions, was tested using different brands of inductors or electronic lamp holders respectively.Results The ultraviolet radiation intensity of lamps in inductance group was significantly higher than that of the electronic group. The maximum difference of the same lamp on different light holders was 44 μw/cm2. The maximum difference in ultraviolet light irradiation intensity between different brands of lamp holders was 30 μw/cm2in inductance group and was 34 μw/cm2 in the electronic group. The inductance lamp holder of Brand A had the highest degree of irradiation while that of Brand X had the lowest.Conclusion Except for the lamp quality, cleanliness and environmental factors, the lamp holder is an important determinant of irradiation intensity of ultraviolet disinfection lamps. This result provides a technical support for daily sanitary supervision.
|
Received: 25 May 2016
Published: 05 January 2017
|
|
|
|
[1] |
付留杰,刘勇,杨筱筠,等.驻济部队宾馆行业卫生状况监督检测调查报告[J].解放军预防医学杂志,2016,36(1):120.
|
[2] |
于瑞华,遇存英.某院校食堂食品卫生量化分级管理评价[J].解放军预防医学杂志,2011,29(6):431.
|
[3] |
杨会锁,于瑞敏,王民,等.某区集训演习食品卫生保障的主要做法和体会[J].解放军预防医学杂志,2013,31(2):160.
|
[4] |
陈学林,刘菁,邹宏.兰州军区空军机关集约化办伙食堂加强食品卫生安全监管的做法和体会[J].解放军预防医学杂志,2014,32(6):547.
|
[5] |
田葆萍,王中民,毛彦杰.某部餐饮单位紫外线消毒灯使用情况调查[J].解放军预防医学杂志,2009,27(1):66.
|
[6] |
刘小燕,李英,邢丽明,等.不同镇流器灯架上紫外线灯辐照度值的差别[J].中国消毒学杂志,2001,18(3):196.
|
[7] |
王文华,于桂香.不同电阻镇流器对紫外线灯辐照度值的影响[J].中国消毒学杂志,1997,14(2):79.
|
[8] |
韩秋霞,李先碧,范文娜,等.不同灯罩对紫外线辐射强度的影响[J].中国消毒学杂志,1992,9(3):166.
|
[9] |
钱巧珍,谢金兰,秦颖,等.镇流器对紫外线灯管辐照强度的影响[J].中国消毒学杂志,2012,29(9):840.
|
[10] |
杜凤芹,李小雷,张瑞芳.镇流器功率大小对紫外线灯辐照强度的影响[J].中国消毒学杂志,2013,30(8):778.
|
[11] |
庞振清,祁业敏,王刚,等.现场检测紫外线灯辐照强度的几点建议[J].中国消毒学杂志,2006,23(1):72.
|
[12] |
金冬,杨映江,揭时红.镇流器输出功率与紫外线灯辐照强度监测调查分析[J].实用预防医学,2005,12(4):378.
|
[13] |
李俊媛,镇流器影响紫外线灯管强度的调查[J].中国医药导报,2010,36(17):86.
|
[14] |
张友林.日本岛津UV-265型紫外-可见光光度计故障检修[J].医疗卫生装备,2006,27(2):92.
|
[15] |
孙彦平,张茜.线光源平板降膜光催化反应器表面光辐照度分布的研究[J].太原理工大学学报,2011,42(3):263.
|
[16] |
秦奋涛,王增波,南景宇,等.养殖专用紫外光源辐照试验研究[J].河北农业大学学报,2007,30(6):97.
|
No related articles found! |
|
|
|
|