Abstract Objective To find out about radiation protection inside radiodiagonsis facilities at 19 hospitals in one area over the past 10 years in order to provide guidance for radiation protection and to control radiation hazards efficiently.Methods According to the national related technical criterions and protection standards, the radiodiagnosis facilities at 19 hospitals in one area were selected as targets of research., Key indexes about radiation protection were statistically analyzed.Results The number of radiodiagnosis facilities was 104 in 2005 and 107 in 2015. Although the number has hardly changed, the radiodiagnosis equipment has been updated over the past ten years. The unqualified percentage of radiation protection indexes has dropped obviously. The unqualified rate associated with radiation leakage from the control station, doors for doctors and doors for patients dropped from 12.5%,18.3% and 21.2% in 2005 to 0%,0.935% and 0.935% in 2015. The 12 work places The ambient dose equivalent rate was above 2.5μSv/h inside twelve facilities in 2005, but wasless than 2.5μSv/h in 2015. The key protection indexes dropped from 57.5%,44.2% and 76.9% to 20.6%,1.87% and 1.87% in 2015.Conclusion The effect of radiation protection has been getting better in 19 hospitals over the past ten years, but the awareness and scope of radiation protection need to be improved.
|
Received: 20 August 2015
Published: 05 January 2017
|
|
|
|
[1] |
郑均正.必须切实强化放射诊疗的安全防护[J].医学研究杂志,2011,40(2):3.
|
[2] |
万玲,马永忠,冯泽臣,等.北京地区放射诊疗设备质量控制状况调查与分析[J].中国医学装备,2014,11(3):10.
|
[3] |
国家质量监督检验检疫总局.GB 18871-2002.电离辐射防护与辐射源安全基本标准[S].北京:中国标准出版社,2002.
|
[4] |
中华人民共和国国家卫生和计划生育委员会.GBZ 130-2013医用X射线诊断放射防护要求[S].北京:中国标准出版社,2013.
|
[5] |
中华人民共和国卫生部.GBZ 165-2012.X射线计算机断层摄影放射防护要求[S].北京:中国标准出版社,2012.
|
[6] |
中华人民共和国卫生部.GBZ 120-2006.临床核医学放射卫生防护标准[S].北京:中国标准出版社,2006.
|
[7] |
曾自力,覃树付.直肠癌术后常规放射治疗摆位误差分析[J].医疗卫生装备,2015,36(6):76.
|
[8] |
庄惠民,朱萍萍,吴琼,等. 医用诊断X射线机房放射防护现状调查[J].环境与职业医学,2009,26(1):83.
|
[9] |
赵国良,朱乐明,邓卫国,等. 某区2015年部分放射工作场所防护检测结果分析[J].灾害医学与救援(电子版),2016,5(2):71.
|
[10] |
孔雪梅,赵进沛,李秀芹,等. 北京军区部队卫生单位放射诊断与防护情况的调查与分析[J]. 解放军预防医学杂志,2014,32(3):231.
|
[11] |
赵进沛,闫妍,程强,等. 北京军区部分CT项目放射防护与设备性能监督监测情况分析[J].中国辐射卫生,2016,25(1):69.
|
[12] |
郭勇,王庆军,张君,等.X线数字断层融合成像与常规DR成像放射剂量比较[J].医疗卫生装备,2014,35(1):98.
|
[13] |
李秀芹,赵进沛,于瑞敏,等. 某地区19所医院介入放射工作场所防护状况调查分析[J].灾害医学与救援(电子版),2016,5(2):67.
|
[14] |
李秀芹,赵进沛,吴欣,等. 军队放射卫生监督监测HACCP质量保证体系的建立[J].职业与健康,2013,29(8):1007.
|
[15] |
李秀芹,吴欣,顾兢,等. HACC在军队放射卫生监督监测质量保证中的建立[J].中国辐射卫生,2013,22(3):274.
|
[16] |
李秀芹,赵进沛,杨新芳,等. 某医院数字X线摄影系统机房建设项目放射防护预评价[J].灾害医学与救援(电子版),2015,4(2):86.
|
[17] |
赵进沛,刘士敏,李秀芹,等.北京军区放射防护工作的回顾与思考[J].解放军医药杂志,2008,26(6):444.
|
[18] |
王修德,孙华斌,杨新芳,等. 部队基层医疗单位放射设备应用存在的问题与对策[J].医疗卫生装备,2009,30(12):95.
|
[19] |
徐忠建,李辉,高文,等. 医用X射线的防护与管理[J].数理医药杂志,2007,20(2):251.
|
[20] |
孙华斌,王修德,唐木涛,等. 军队医用放射防护规范化管理的理论和实践研究[J].中国辐射卫生,2010,19(2):157.
|
No related articles found! |
|
|
|
|