Home  About Journal Instructions for Authors Editorial Board Subscribe Advertisement Messages Board 中文

CJAP ›› 2015, Vol. 31 ›› Issue (4): 322-326.doi: 10.12047/j.cjap.0111.2015.006

• ORIGINAL ARTICLE • Previous Articles     Next Articles

Evidence of waveform information in arterial blood gas by beat-by-beat sampling method in patients with heart failure

YAO You-xiu1,2, SUN Xing-guo1,△, LI Jun1, TAN Xiao-yue1, ZHANG Hong-liang1, WANG Gu-yan1, GE Wan-gang1, LIU Fang1,3, LI Hao1, CI Zheng1,3, HU Sheng-shou1   

  1. 1. State Key Laboratory of Cardiovascular Disease, National Center of Cardiovascular Diseases Fuwai Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100037;
    2. Department of Anesthesiology, The 3rd Affiliated Hospital, Beijing University, Beijing 100083;
    3. Department of Clinical Medicine, Weifang Medical College, Shandong Weifang 261000, China
  • Received:2015-04-20 Revised:2015-07-05 Published:2021-11-12

Abstract: Objective: We investigate the magnitudes of waveform changes of arterial blood gas (ABG) in patients with heart failure. Methods: Five patients with heart failure were selected, continuous collecting radial artery blood and measured PaO2, PaCO2, pHa and SaO2. We selected two typical breaths cycles of waveform changes of ABG from each patient for data analysis. Comparison of the adjacent highest and lowest values to verify the presence of a periodic waveform changes of ABG, and in addition, we used t test to analysis the range of waveform changes of ABG in patients with heart failure and patients with normal cardiac function and compared whether the difference between them. Results: The 5 patients (2 surgical and 3 ICU) with heart failure, were 4 male and 1 female, (69±7)year, (169±10)cm, (75±19)kg, LVEF=(38±3)%. The heart beat numbers for full blood into the blood sampling pipe were 17±2, and all covered more than 2 breath cycles. There were significant changes of PaO2, PaCO2, [H+]a and SaO2(P<0.05). The magnitudes of changing PaO2, PaCO2, [H+]a and SaO2 were (7.94±2.02)mmHg, (1.18±0.56)mmHg, (0.54±0.17)nmol/L and (0.21±0.07)%, and they were (6.1±1.5)%, (3.2±1.5)%, (1.5±0.5)% and (0.2±0.1)% from their mean respectively. Even these magnitudes fo all ABG parameters were trendily lower than those of patients with normal cardiac function, but only PaO2 and [H+]a were significant (P<0.05). Conclusion: Using this simple continuous beat-by-beat arterial blood sampling method, we obtained a clear evidence of periodic waveform of ABG parameters following by breath cycle in patients with heart failure, but the magnitude trendily be decreased.

Key words: heart failure, arterial blood gas, respiratory regulation, beat-by-beat arterial blood sampling, waveform signal

CLC Number: 

Contact Email:editor@cjap.ac.cn
Copyright © 2015 CJAP, All Rights Reserved.
Powered by Beijing Magtech Co. Ltd